Control units

VIACONTROL

Traffic light control unit

VIACONTROL is the advanced traffic light control unit designed for intelligent management of 2 traffic lights with 2 or 3 signals. Made entirely in Italy with top-quality materials, this unit embodies the excellence of Made in Italy in access automation. Thanks to the 2.2" color LCD display and the programming logics, it ensures fast and intuitive configuration, offering high reliability for industrial and civil safety with extremely low energy consumption.

Main Applications

  • Traffic regulation and safety in multi-storey and underground car parks: optimized management of ramps and alternating one-way systems
  • Industrial safety and logistics: flow control of heavy vehicles in loading/unloading areas and industrial driveways
  • Residential access automation: management of apartment building gates with facilitated exits via sensors or timers
  • Optical signaling device for construction sites and passages: timed or priority regulation for narrow passages and private roads

Technical data

VIACONTROLVIACONTROL12
Board Power Supply24-230 Vac/dc (separate power supply)12 Vac/dc
Consumption0.01 A0.02 A
Traffic Light Power Supply24-230 Vac/dc (single external input)12-230 Vac/dc (single external input)
Accessories Power Supply24 Vdc*, max 0.5 A12 Vdc**, max 0.5 A
Controlled Traffic LightsMaximum 2 traffic lights, up to 3 lights each
Inputs3 inputs (2 for traffic lights + 1 for emergency/alarm)
Auxiliary Outputs2 AUX outputs (NO/NC contacts)
Max AUX Load48 Vac/dc, 0.5 A
Display2.2" color LCD
Serial PortFor firmware updates and expansions
Protection2A fuse for traffic light management
MountingDIN Rail
Operating Temperature-20/+60 °C
DimensionsWidth 106 mm x Height 90.2 mm x Depth 57.9 mm

*The accessories output actually supplies about 22.5 Vdc: check that the connected devices (sensors, photocells, receivers) also work below 24 V. Devices that need at least 24 V must be powered separately.

**The accessories output actually supplies about 10.5 Vdc: check that the connected devices (sensors, photocells, receivers) also work below 12 V. Devices that need at least 12 V must be powered separately.

Operating logics

  • RESERVATION: the green light cycle is activated by command devices such as sensors or buttons connected to Input 1 and 2. This is the optimal mode for managing variable traffic flows safely
  • TIMING: cyclical operation based exclusively on the preset times (TV1, TV2, and TSG). It does not require external sensors
  • STATE: the traffic light switches to green and remains green for the entire duration of the physical activation of the input, regardless of any timers
  • TESTING: A mode reserved exclusively for internal product testing by the manufacturer's personnel

Timing parameters

ParameterDescriptionRangeDefault
TV1Green time traffic light 1 (and red traffic light 2)0 - 999 s10 s
TV2Green time traffic light 2 (and red traffic light 1)0 - 999 s10 s
TSGArea clearance time (all red)0 - 999 s10 s
TAROrange light or pre-flash time0 - 999 s0 s
TAUX 1/2Auxiliary output activation time0 - 999 s10 s

Installer notes

  • Simplified wiring: the common pole of the traffic light 1 and 2 terminal blocks is connected internally; it is enough to connect the common on one terminal block only
  • Diagnostics: by pressing and holding the ESC button for 3 seconds, the firmware version and serial number can be viewed on the display
  • Safety: in the event of an alarm (Input 3 activation), the unit can be configured to trigger a "flashing red" state

Certifications

Drawings

Manuals and instructions

All user manuals →

Frequently asked questions

Does VIACONTROL run on 12 V, 24 V or 230 V?

The VIACONTROL control unit runs on 24 V or 230 V. The traffic lights can instead have any supply voltage (e.g. 24 V or 230 V), because it is handled separately through a dedicated terminal: the control unit acts as a switching element. If you have a 12 V power source, choose the VIACONTROL12 model.

What happens if cars arrive from both sides?

In Priority mode the control unit serves one side at a time: after the green and clearance phase it moves to the other side. With simultaneous calls it gives way to the side that activated input 1 or 2 first; if both inputs stay active, the green alternates between the two sides according to the set times.

How do I size the TSG clearance time?

TSG is the time the slowest vehicle needs to cover the whole alternating one-way section, plus a suitable safety margin. During this phase both traffic lights stay red, so that the section is completely clear before the direction of travel is reversed, i.e. before the green passes to the opposite traffic light.

What does Status mode do?

The traffic light turns green and stays green for as long as its input is active, with no timer; if both commands arrive together the control unit sets everything to red.

What happens in an emergency?

When input IN3 is activated, the control unit switches to the alarm state chosen with function F4, for example flashing reds.

What are the AUX outputs for?

Two configurable NO/NC contacts (48 V ac/dc, 0.5 A) to drive gates, barriers, alarms or signage without an extra relay board.

One side gets much more traffic: can I give it priority?

Yes, with the queue clearing function: if, during the green time (on either side), another vehicle arrives on the side that has the green, the green time in progress is reset and starts again from 0.

Alternative Products

SATU​RNO:

  • Management capacity: supports up to 10 traffic lights (2 or 3-light models), exceeding the limits of standard systems for managing complex transit flows
  • Programming: advanced interface with an integrated Web Server via local Wi-Fi; allows full configuration from a smartphone or PC via browser, requiring no dedicated software

News and insights

Warranty and terms of sale

The warranty policies adopted by Stagnoli are set out in the General Terms and Conditions of Sale and naturally follow the legal rules on post-sale warranties (duration, proof of purchase, start date), which we summarise below:

  • 12 months B2B, from the date shown on the proof of purchase (mandatory)
  • 24 months B2C, from the date shown on the proof of purchase (mandatory)
Was this page helpful?Updated: October 2026